Archive of the journal «Russian otorhinolaryngology» - Medical scientific journal «Russian otorhinolaryngology»

Medical Scientific Journal
Russian
Otorhinolaryngology
9, Bronnitskaya Str., Saint Petersburg, 190013, Russia
Tel./Fax: (921) 922-36-77, e-mail: text@pfco.ru
 ISSN 2413-4309 (online), ISSN 1810-4800 (print)  
Rossiiskaya otorinolaringologiya
Go to content
◄◄   |    ◄
►   |    ►►
Section: Section Otiology
Experimental study of influence of piezoelectric device on acoustic analyzer
F. V. Semenov (1), Yu. I. Dorofeeva (2), G. V. Chernyak (3), V. S. Untevskii (4)
(1), (2), (3), (4) Kuban State Medical University, Krasnodar, 350007, Russian Federation
UDK: УДК 616.282.7-089-092.9:615.837:616.28-009
DOI: https://doi.org/10.18692/1810-4800-2024-4-77-83
ABSTRACT
Abstract. Objective. To study in experiment the influence of the piezoelectric device on the auditory analyzer, the possibility of developing sensorineural hearing loss during the formation of a trepanation cavity in the area of the skull bones of laboratory animals. Material and methods. The work was carried out on the basis of the vivarium of the Kuban State Medical University on rabbits: 10 individuals of the Soviet chinchilla breed. The animals were divided into two groups. In the first group, the rabbits were sedated to test hearing thresholds without surgical treatment. In another group, also under sedation, an open bone wound was simulated in the area of the occipital protuberances of the parietal region of a rabbit using a piezoelectric device and testing hearing thresholds. Before surgery and on the 10th day, in both groups of the study, short-latency auditory evoked potentials were recorded. The potentials were recorded sequentially binaurally in response to a click. Conclusion. Assessment of the results of hearing thresholds by brainstem auditory evoked response recordings did not reveal a negative effect on the function of the auditory analyzer when exposed to a piezoelectric device in the area of the bone structures of the skull in experimental animals according to data obtained from recording short-latency auditory evoked potentials. Design. Prospective pilot study.
Publication date:
09.08.2024
Keywords:
audiometry; sensorineural hearing loss; piezoelectric device
For citation:
Semenov F. V., Dorofeeva Yu. I., Chernyak G. V., Untevskii V. S. Experimental study of influence of piezoelectric device on acoustic analyzer. Russian Otorhinolaryngology. 2024;23(4):77-83. (In Russ.) https://doi.org/10.18692/1810-4800-2024-4-77-83
All rights to this publication are registered. Link to Russian Otorhinolaryngology Journal is required.
Reprinting of both individual articles and the Journal itself without the publisher`s permission is prohibited.
The Journal editors and publisher are not liable for the content and accuracy of advertising information.
© St. Petersburg Research Institute of Ear, Throat, Nose, and Speech of the Ministry of Health of Russia
© Scientific Clinical Center of Otorhinolaryngology, FMBA of Russia
Логотип журнала "Российская оториноларингология"
© Co. Ltd. Polyforum Group, 2012—
Яндекс.Метрика
Back to content